in Education by
A single wattmeter is connected to measure the reactive power of a three-phase, three-wire balanced load. The line current is 17A and the line voltage is 440V. Calculate the power factor of the load if the reading of the wattmeter is 4488 VAR. (a) 0.6 (b) 0.8 (c) 1 (d) 1.2 The question was posed to me in an online quiz. I'm obligated to ask this question of Power Measurement in Three-Phase Circuits in chapter Polyphase Circuits of Network Theory Select the correct answer from above options network theory questions and answers, network theory questions pdf, network theory question bank, network theory gate questions and answers pdf, mcq on network theory pdf, gate network theory questions and solutions, network theory mcq Test , ies network theory questions, Network theory Questions for GATE EC Exam, Network Theory MCQ (Multiple Choice Questions)

1 Answer

0 votes
by
Right answer is (b) 0.8 To explain I would say: Wattmeter reading = VLILsinØ => 4488 = 440 x 17sinØ => sinØ = 0.6. Power factor = cosØ = 0.8.

Related questions

0 votes
    The wattmeter method is used to measure power in a three-phase load. The wattmeter readings are 400W and -35W. ... for GATE EC Exam, Network Theory MCQ (Multiple Choice Questions)...
asked Oct 17, 2021 in Education by JackTerrance
0 votes
    A symmetrical three-phase, three-wire 440V supply is connected to star-connected load. The impedances in each branch ... EC Exam, Network Theory MCQ (Multiple Choice Questions)...
asked Oct 17, 2021 in Education by JackTerrance
0 votes
    A three-phase balanced delta connected load of (4+j8) Ω is connected across a 400V, 3 - Ø balanced supply. ... for GATE EC Exam, Network Theory MCQ (Multiple Choice Questions)...